Leica TCR 407

Tehnical specifications
 
Angle measurments (Hz, V)
Method Absolute continous
Display resolution 1" / 0.1 mgon / 0,01 mil
Standard Deviation (ISO 17123-3) 7"(2mgon)
Telescope
Magnification 30x
Field of view 1 30 ( 26m at 1 km)
Min. target distance 1.7 m
Reticle illuminated
Compensator
System Electronic 2 axis oil compensator
Setting accuracy 2"
Distance Measurement on Reflector (IR)
Measuring range with circular prism GPR1 3500 m
Measuring with reflective foil (60mm x 60 mm) 250 mm
Standard deviation (ISO 17123-4) (fine/quick/tracking) 2 mm + 2 ppm/55 mm + 2 ppm/5 mm + 2 ppm
Time for a measurment (fine/quick/tracking) < 1 sec/ < 0.5 sec/ < 0.15 sec
PinPoint-Reflectorless Distance measurment ( RL)
Range: PinPoint R100 ("power") 170 m (90reflective)
(Medium atmospheric conditions) PinPoint R300 ("ultra") > 500 m 90% reflective)
  Lasr at GPR circular reflector 7500 m
Standard deviation (ISO 17123-4) 3 mm+2ppm/5mm+2ppm
(Norma/Tracking)  
Time per meas. )Normal/Tracking) typ. 3s/1s
Point size at 100m 12 mm x 40 mm
Communication
Internal data storage 10 000 data blocks
Interface RS232
Data formats GSI/IDEX/ASCII/dxf/Freely definable formats
Operation
Display Graphics 160 x 280 pixels, Apha numeric 8 lines x 31 characters
Laser plummet
Type Laser point, brightness adjustable in steps
Accuracy 1.5 mm at 1.5 m instrument height
Environmental conditions
Temperature range (operation) -20ºC to +50ºC (-4ºF to +122ºF)
Dust and splash proof (IEC 60529) IP55
Humidity 95 &, non condensing
Weight
Weight including battery and tribrach 5.2 kg
Operating period with GEB121 approx. 6 hours
Number of distance measurments with GEB1212 approx 9'000